0 troubleshooting – Nexen RSD200 964531 User Manual

Page 22

Advertising
background image

FORM NO. L-21161-E-0108

22

10.0 TROUbLeShOOTINg

Problem

Possible Cause

quick Test

Corrective Action

Green LEDs are not lit.

No power to RSD200
board

Place the positive lead of Volt Meter on RED wire

and Negative Lead on bLACK wire. Should
meausre +24VDC.

If proper voltage is not measured: check wire
connections and/or replace power supply.

Connection failed error

when CONNECT icon

is pressed, or PC is
not communicating

with RSD200.

RSD not powered up

Green LEDs, I1 and I2, on board should be lit.

Apply proper power to RSD200.

Cable not connected

Ensure cable is connected from PCs RS232 port to
P5 on the RSD200 board.

Connect cable properly.

Faulty RS232 cable

Test continuity of cable (See Figure 5).

Replace cable if faulty.

Jumper W2 in wrong

position

Inspect position of W2.

Move W2 to position 1.

bad Port number error
is reported when
CONNECT icon is
pressed.

Wrong serial port is
selected.

None

Select Communications Setup and switch to
another port.

Digital Inputs not
responding.

Improper jumper

selection.

Check Jumpers W5 and W6 (Refer to Jumper &
Switch Settings).

Set jumpers properly and test again.

Input signals to RSD200
not being toggled.

Toggle the inputs and check for proper voltage
changes (Refer to SPECIFICATIONS Section)

Set signal up properly and test again. Yellow
LEDs, I5 &/or I6, should light when input is high.

RSD200 output does
not move when the
machine is started.

Start/Stopped Signal is
not setup correctly.

The green trend line on the Diagnostics screen
should show the Start/Stopped signal high when
the machine is running.

Check the setup and make sure rotary switch
selection is correct for the type of Start/Stopped
signal used.

RSD200 is in MANUAL
mode.

Check SWITCH TO MANUAL button on the
Diagnostics window.

Press the SWITCH TO MANUAL bUTTON and

then SWITCH TO AUTOMATIC when the

manual operations window appears.

RSD200 output

changes, but the
dancer arm does not
move.

No air pressure to brake.

Use RSD200 setup screen to set Stopped Output

to 100% and test if roll can be rolled by hand.

Troubleshoot pneumatic air circuit and check the

pressure to the brake or clutch.

Output limits are not set
correctly.

Use RSD200 Setup screen to check the Maximum

and Minimum Output Limits.

Set Maximum and Minimum Output Limits
according to output range required (Refer to
SETUP section).

Tension is set too high
on machine.

Reduce the dancer pressure/weight and test again.

If you have a multi-piston brake, make sure there
are enough brake pistons engaged.

No air pressure in roll

core.

Core shaft should turn when the machine runs.

Apply proper air pressure to core and test again.

Dancer Setpoint set
improperly.

Use RSD200 Tuning window to check the
DANCER SETPOINT %

Start with a DANCER SETPOINT of 50% (See
the INSTALLATION section.)

brake Clutch, or Drive

does the opposite of
what it should.

Controller action is
backwards.

The brake output goes to minimum when the dancer
arm storage is at the maximum or vise versa.

Change Jumper W1 setting (Refer to Jumper
and Switch settings).

When machine speed

is constant, dancer arm
cycles continuously

above and below
setpoint or between
max and minimum limit.

Gain is set too high.

Reduce Gain and see if arm stops cycling.

Refer to the TUNING section.

Tension compensation

not setup correctly
(RSD200P only)

Measure tension on machine and see if it is close to

the tension displayed on the RSD200 Diagnostics
screen.

Refer to SENSOR CALIbRATION section.

RSD200 output goes

to 0% output during
acceleration (brake
applications only).

Machine acceleration is

too fast.

None

For a dancer control to work properly, the
machine acceleration should be set so that

some braking is used during acceleration. When
the output to the brake is 0%, the RSD200 has
no control over the dancer position.

Advertising