Nexen RSD200 964531 User Manual

Page 16

Advertising
background image

FORM NO. L-21161-E-0108

1

For most applications the basic Tuning Parameters will

be sufficient to tune the RSD200.

The Advanced Tuning Parameters are for applications

with unique requirements such as:

• extremely fast accelerations/decelerations

• zero web tension during stops

• frequent starts and stops

System Integrators appreciate these parameters as they

provide the flexibility to customize the control system

similar to that of hardware based control boards.

Select ShOW ADVANCeD from the Tuning window.

NOTe: The following parameters have all been set to

a factory default.

D

aMPening

DAMPENING effects how responsive the controller

is. Once GAIN has been set, DAMPENING can be

adjusted to make the control more sluggish (larger

number) or more responsive (smaller number). The

default setting will work for most applications, but if the

dancer arm experiences high frequency movement due to

out-of-round rolls or vibrations, increase DAMPENING.

M

iniMuM

a

DaPtatiOn

MINIMUM ADAPTATION is the beginning point for

ADAPTATION after an adaptation reset caused whenever

the dancer arm is at the maximum storage position while

the RSD200 is stopped. If dancer arm oscillations persist

when starting near core, then reduce the MINIMUM

ADAPTATION in increments of 0.5 and test again.

M

axiMuM

a

DaPtatiOn

MAXIMUM ADAPTATION is the maximum limit of the

Adaptation Term. This parameter is useful to limit how

high the RSD200 ADAPTATION value can go. If the

ADAPTATION value rises too high and causes dancer

arm oscillations, lower the value to prevent oscillations.

a

DaPtatiOn

R

ate

ADAPTATION RATE effects how fast the controller

adapts to a roll’s diameter and inertia. If you set the

parameter too low, the control will be slow to adapt.

This can cause the dancer arm to slowly oscillate about

the SETPOINT during start-up. If set it too high, at core

the RSD200 will adapt very rapidly, causing the gain to

become too large and the dancer arm to oscillate quickly.

. ADVANCeD TUNINg PARAmeTeRS

Figure 1

The RSD200 will maintain the dancer arm position at the dancer SETPOINT value when the machine is running. The

RSD200 will still be active when the machine is stopped. For most applications, the Dancer SETPOINT is set to 50%.

However, the Dancer SETPOINT can vary from 50% to provide more or less web storage depending on the machine’s

acceleration and deceleration requirements.

DANCER SETPOINT values range from 0% minimum storage position to 100% maximum storage position and can be

found in the DANCER SETPOINT pane of the TUNING window.

.2 DANCeR SeTPOINT

Advertising
This manual is related to the following products: