+2 VDC & DC Common: RSD200 requires 24 VDC to

operate (Refer to SPECIFICATIONS for current rating).

Sensor excitation: This output provides +12 VDC

as an excitation voltage for dancer arm position

sensors such as Nexen’s older DPS 30 or DPS 60

sensors and mechanical potentiometers (Refer to the

SPECIFICATIONS section for current rating.) If using

Nexen’s DPS30A or DPS60A sensors, note that the

excitation voltage required is +24 VDC.

Position Sensor Input: The position sensor input is

a 0–10 or 0–12 VDC signal that is provided from the

dancer arm position sensor. The choice of voltage range

is selected by Jumper W3 (Refer to Figure 7). For best

results the voltage range should match the dancer arm

swing (i.e.: a 30° dancer arm swing should produce

nearly a 0–10 VDC or 0–12 VDC position signal).

Start/Stopped Signal or RS22 Receive: This input

has two functions: first, to accept a Start/Stopped

Signal; and second, to act as the receive line for RS232

communications. The function is chosen by Jumper W5

(Refer to Figure 7).

As a Start/Stopped input, this signal uses Isolated DC

Common as a return. When 12-24 VDC is applied, the

controller will respond according to how this input was

setup (refer to Start/Stopped Signal Selection Section).

This feature tells the RSD200 controller when the

machine starts and stops. A yellow indicator, I6, on the

controller’s printed circuit board will be on when 12-24

VDC is present at this input.

As the receive line (Rx) for RS232 communications,

this input, the next input (Tx), and DC Common are all

that is needed to communicate with the RSD200 (Refer

to Figure 5). RSD200 setup, tuning and diagnostic

parameters can be sent back and forth between the

controller and other devices such as a PLC or computer

by using RS232. When using this input as the receive

line for RS232 communications, the Start/Stopped

Signal command has to be sent via this communications

link (See Communications Protocol in the Appendix).

Splice or RS22 Send: This input has two functions:

first, to accept the Splice signal; and second, to act as

the send line for RS232 communications. The function is

chosen by jumper W6 (Refer to Figure 7).

As the Splice input, this signal uses the Isolated DC

Common as a return. When 12-24 VDC is applied

momentarily, the current ADAPTATION value will change

to NEW ROLL ADAPTATION value (See TUNING and

OPERATION sections) and the RSD200 will adapt

to the new roll or core. A yellow indicator, I5, on the

controller’s circuit board will be on when 12-24 VDC is

present at this input.

As the send line (Tx) for RS232 communications, this

input, the previous input (Rx), and DC common are all

that is needed to communicate with the RSD200 (Refer

to Figure 5). RSD200 setup, tuning and diagnostic

parameters can be sent back and forth between the con-

troller and other devices such as a PLC or computer by

using RS232. When using this input as the send line for

RS232 communications, the Splice command has to be

sent via this communications link (See Communications

Protocol in the Appendix).

Control Signal Output: This output signal can be used

as an input to a current or voltage-to-pressure converter

or as a control signal to a motor drive. The output is

chosen by jumper W7 (Refer to Figure 7). The output

can be set to 0–10 VDC or 4–20 mA. both ranges are

already calibrated and ready for use.

Isolated DC Common Input: In cases where isolated

Start/Stopped and Splice inputs or Control Signal Output

is desired, this input is the return line for the isolated

power supply (user supplied). If isolation is not needed,

this input must be connected to DC Common input.

Isolated +2 VDC Input: In cases where isolated Start/

Stopped and Splice inputs or Control Signal Output is

desired, this input is the supply line for the isolated 15-

24 VDC power supply (user supplied). If no isolation is

needed, this input must be connected to the +24 VDC

input (Refer to Figure 4).

Figure 

RSD200 electrical Connections

Sensor Excitation

+24 VDC
DC Common

Position Sensor Input

Not Used

Not Used

Start/Stopped, Rx

Isolated DC Common Input

Control Signal Output

Splice, Tx

Isolated +24VDC Input

RSD200

1.2 eLeCTRICAL CONNeCTIONS

Advertising