.2 Web TeNSION - RSD200P ONLY

If the machine’s tension setpoint varies more than

+/- 50%, RSD200 performance can be improved with

tension compensation. Improved performance will allow

faster machine accelerations & decelerations.

If the machine’s tension setpoint does not vary more than

+/- 50%, or the Tension Compensation is not chosen, the

WEb TENSION CALIbRATION window can be left with

default values in the PRESSURE and TENSION fields.

Setting up tension compensation involves calibrating

the RSD200 to convert Dancer Arm loading pressure

into total tension. Consequently, total web tension must

be physically measured (or calculated) for minimum and

maximum tension during the setup process.

Figure 12

h

igh

t

enSiOn

1. Repeat the steps in LOW TENSION section at maxi-

mum tension.

2. Press the SeND button to send the Web TeN-

SION CALIbRATION values in the RSD200.

machine with Tension measurement System:
1. Setup the web machine with the minimum tension.

2. Run the machine at a slow run speed and adjust the

output of the RSD200 manually until the dancer arm
is stable.

3. Enter the measured web tension and Dancer Arm

loading pressure values in the Low Tension fields of
the Web Tension Configuration window.

machine without Tension measurement System:
1. Set the dancer pressure to the minimum.

2. With a scale, measure the force it takes to hold the

dancer arm in its operating position.

.0 SeNSOR CALIbRATION

Figure 11

The Dancer Arm Position Sensor must be calibrated

before the RSD200 can operate properly.

1. Select DANCER RANGE.
2. Follow the displayed instructions.

Calibration involves moving the dancer to each of its

limits and pressing the appropriate DANCER RANGE

buttons. The direction of dancer arm movement is

automatically accounted for in this calibration process.

.1 DANCeR RANge

Select the Sensor Calibration icon in the toolbar.

3. Use the following formula to calculate total web ten-

sion: Total Tension = Force Measurement / ((Number
of dancer rollers)•2).

4. Enter the web tension and Dancer Arm loading

pressure values in the Low Tension fields of the Web
Tension Configuration window.

Select Web Tension from Sensor Calibration Window.