Nexen RSD200 964531 User Manual

Page 9

Advertising
background image

9

FORM NO. L-21161-E-0108

1. RSD200P PNeUmATIC CONNeCTIONS

Nexen developed the RSD200P for applications that would benefit from tension setpoint compensation. The

RSD200P features an integral pressure sensor that connects to the air supply pressure of the dancer arm loading

cylinder. As the tension setpoint changes via the air pressure of the loading cylinder, the RSD200P measures this

change and adjusts its performance accordingly. The RSD200P pressure sensor’s calibration procedure is explained

in the SENSOR CALIbRATION section.

RSD200P

Brake,
Clutch,
or Drive

Control
Output
Signal

Pneumatic
Loading
Cylinder

User Supplied
Air Pressure

Current or Voltage-to-Pressure Converter

Tension
Setting Air
Pressure
Regulator

Figure 

M

iniMuM

C

OnneCtiOnS

n

eCeSSaRy

F

OR

P

neuMatiC

B

Rake

OR

C

lutCh

a

PPliCatiOn

:

The RSD200 requires a +24 VDC Power Supply,

Dancer Arm Position Sensor, Current- or Voltage-to-

Pressure Converter, and a dry circuit contact or switch

for any pneumatic brake or clutch applications. (Refer to

Figure 4).

2 VDC Power Supply: Provides the power for

operation (Refer to SPECIFICATIONS for details).

Dancer Arm Position Sensor: Provides an analog

signal that tracks dancer arm movement.

Current- or Voltage-to-Pressure Converter: (ex.

Nexen’s EN50 or EN40) Converts the appropriate

control output (i.e. 4-20 mA or 0-10 VDC) into air

pressure for use with a pneumatic brake or clutch.

Start/Stopped Signal: Lets the RSD200 know when

the web is moving or stopped.

M

iniMuM

C

OnneCtiOnS

n

eCeSSaRy

F

OR

M

OtOR

D

Rive

a

PPliCatiOn

:

The RSD200 requires a +24 VDC Power Supply, Dancer

Arm Position Sensor, optional second power supply,

and a dry circuit contact or switch for a motor drive

applications. (Refer to Figure 4).

2 VDC Power Supply: Provides the power for operation

(Refer SPECIFICATIONS for details).

Dancer Arm Position Sensor: Provides an analog signal

that tracks dancer arm movement.

Optional Power Supply: Used when isolated inputs or

outputs are required. Most commonly used to prevent

the mixing of power supply commons together when

connecting the analog output to a motor drive (Refer to

SPECIFICATIONS for details).

Start/Stopped Signal: Lets the RSD200 know when

the web is moving or stopped.

1. JUmPeR & SWITCh SeTTINgS

Make the appropriate Jumper and Switch Settings shown below for your application. The RSD200 printed circuit-

board can be removed to allow access to all jumpers and switches.

B

OaRD

R

eMOval

i

nStRuCtiOnS

:

1. Remove power from RSD200.
2. Disconnect the Power and Signal Cable Connectors from the RSD200 base.
3. Move the printed circuit board side-to-side while pulling to remove board.

NOTe: Factory installed fitting

accommodates .2 inch tubing.

A fitting for mm tubing is also

included with the RSD200.

Advertising