Nexen RSD200 964531 User Manual

Page 13

Advertising
background image

1

FORM NO. L-21161-E-0108

2.0 COmmUNICATIONS SOFTWARe SeTUP

Figure 10

2.1 TORqUe ACTUATOR

Select the type of actuator the RSD200 will control

“pneumatic brake/clutch” or “drive or magnetic particle.”

2.2 UNWIND OR WIND

Select whether the RSD200 will control a wind or

unwind dancer arm.

The MINIMUM and MAXIMUM OUTPUT settings

override all other settings and allow the RSD200

OUTPUT to be limited. Generally the MINIMUM and

MAXIMUM will be set at 1 and 100% respectively.

These values may need adjustment for some applications.

example One: Air supply pressure exceeds the

maximum air pressure rating of a brake or clutch. For

instance, an I/P transducer can supply 125 psi to a brake

rated for 80 psi. The MAXIMUM OUTPUT % should be

set as follows:

MAXIMUM OUTPUT % = (maximum brake pressure /

supply air pressure) * 100 = (80 / 125)*100 = 64%

example Two: A pneumatic brake or clutch that is spring

disengaged; In this case the MINIMUM OUTPUT %

would be set high enough to overcome the spring and

allow the friction facing to lightly contact the rotor.

The STOPPED OUTPUT setting is used to limit how high

the output can go while the RSD200 is in STOPPED

mode. This value supersedes the MAXIMUM OUTPUT

value during stopped conditions. It is used in applications

when the machine is stopped and a small amount of

drag tension is desired on the web. If the STOPPED

OUTPUT function is not needed then make it equal to the

MAXIMUM OUTPUT value.

2. OUTPUT LImITS

2. UNITS

Select English (psi & lb force) or Metric (kPa & Newtons).

Press the SeND button to send the SeTUP values to

the RSD200.

Select the setup icon in the toolbar.

Advertising