Altera_fp_acc_custom signals, Altera_fp_acc_custom signals -3, Altera_fp_acc_custom – Altera Floating-Point User Manual

Page 44

Advertising
background image

Related Information

Fitter Resources Reports

Provides information about Quartus II resource utilization

ALTERA_FP_ACC_CUSTOM Signals

Figure 4-1: ALTERA_FP_ACC_CUSTOM

clk

n

ALTERA_FP_ACC_CUSTOM

r

x

areset

en

xo

xu

ao

Table 4-2: ALTERA_FP_ACC_CUSTOM Input Ports

Port Name

Required

Description

clk

Yes

All input signals, otherwise explicitly stated, must be synchronous to

this clock

areset

Yes

Asynchronous active-high reset. Deassert this signal synchronously to

the input clock to avoid metastability issues.

en

No

Global enable signal. This port is optional.

x

Yes

Data input port.

n

Yes

Boolean port which signals the beginning of a new data set to be

accumulated. This should go high together with the first element in the

new data set and should go low the next cycle. The data sets may be of

variable length and a new data set may be started at any time. The

accumulation result for an input will be available after the reported

latency.

Table 4-3: ALTERA_FP_ACC_CUSTOM Output Ports

Port Name

Required

Description

r

Yes

The running value of the accumulation.

UG-01058

2014.12.19

ALTERA_FP_ACC_CUSTOM Signals

4-3

ALTERA_FP_ACC_CUSTOM IP Core

Altera Corporation

Send Feedback

Advertising