background image

Figure 5-2: ALTFP_ADD_SUB

dataa[]

datab[]

add_sub

clock

clk_en

inst

ALTFP_ADD_SUB

result[]

overflow

nan

underflow

zero

aclr

Table 5-4: ALTFP_ADD_SUB Input Ports

Port Name

Required

Description

aclr

No

Asynchronous clear input for floating-point adder or subtractor. The

source is asynchronously reset when the

aclr

signal is asserted high.

add_sub

No

Optional input port to enable dynamic switching between the adder

and subtractor functions. The

add_sub

port must be used when the

DIRECTION

parameter is set to

VARIABLE

. When the

add_sub

port is

high,

result[] = dataa[] + datab[]

, otherwise,

result[] =

dataa[] - datab[]

.

clk_en

No

Clock enable to the floating-point adder or subtractor. This port allows

addition or subtraction to occur when asserted high. When asserted

low, no operations occur and the outputs are unchanged.

clock

Yes

Clock input to the IP core.

dataa[]

Yes

Data input to the floating-point adder or subtractor. The MSB is the

sign bit, the next MSBs are the exponent, and the LSBs are the

mantissa bits. The size of this port is the total width of the sign bit, the

exponent bits, and the mantissa bits.

datab[]

Yes

Data input to the floating-point adder or subtractor. This port is

configured in the same way as

dataa[]

.

Table 5-5: ALTFP_ADD_SUB Output Ports

Port Name

Required

Description

nan

Yes

NaN exception output. Asserted when an illegal addition or subtraction

occurs, such as infinity minus infinity. When an invalid addition or

subtraction occurs, a NaN value is output to the

result[]

port. Any

adding or subtracting involving NaN values also produces a NaN value.

UG-01058

2014.12.19

ALTFP_ADD_SUB Signals

5-5

ALTFP_ADD_SUB IP Core

Altera Corporation

Send Feedback