Installation, Continued, Floor clearances – Desa CGD3018PT/NT User Manual

Page 11

Advertising
background image

www.desatech.com

111160-01C

11

Minimum
Noncombustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Set
18", 24",
30" Mode

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050,
GA6052)

Top of
Fireplace
Opening

Underside
of Mantel
Shelf

Mantel Shelf

INSTALLATION

Continued

Figure 8 - Minimum Mantel Clearances

When Using Hood

(GA6050,
GA6052, and
GA6053)

All
Models

NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

14"
Min.

Combustible
Material

Noncombustible
Material

Hearth

5"
Min.

Combustible
Material

Figure 10 - Minimum Fireplace

Clearances Above Combustible Flooring

Figure 9 - Minimum Fireplace Clearances

if Installed at Floor Level

FLOOR CLEARANCES

A. If installing appliance on the floor level, you

must maintain the minimum distance of 14"
to combustibles (see Figure 9).

B. If combustible materials are less than 14" to the

fireplace, you must install appliance at least 5"
above the combustible flooring (see Figure 10).

INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION

Note:

When used as a vented heater, appliance

must be installed only in a solid-fuel burning fire-
place with a working flue and constructed of non-
combustible material.
If your heater is a manually controlled model, you
may use this heater as a vented product. There are
three reasons for operating your heater in the
vented mode.
1. The fireplace does not meet the clearance to com-

bustibles requirements for vent-free operation.

2. State or local codes do not permit vent-free

operation.

3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to or-
der, see Accessories, page 43). This will insure
vented operation (see Figure 11). The damper
clamp will keep damper open. Installation instruc-
tions are included with clamp accessory.

Figure 11 - Attaching Damper Clamp

Manufactured

Fireplace

Masonry

Fireplace

Damper

Damper
Clamp

Damper

Damper
Clamp

Damper