Installation – Desa CGD3018PT/NT User Manual

Page 9

Advertising
background image

www.desatech.com

111160-01C

9

INSTALLATION AND CLEARANCES
(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

18", 24", 30"

16"

42"

LOG SIZING REQUIREMENTS

Minimum Firebox

Log

Front

Rear *

Size

Height

Depth

Width

Width

18"

17"

14"

24"

20"

24"

17"

14"

28"

21"

30"

17"

14"

34"

24"

* Measured at 14" depth.
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured fireplace, or certified vent-free
firebox.

Minimum Clearances For Side
Combustible Material, Side Wall, and
Ceiling
A. Clearances from the side of the fireplace cabi-

net to any combustible material and wall
should follow diagram in Figure 5.
Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and pro-
trudes 3

1

/

2

" from the wall. This combustible

material must be 4" from the side of the fire-
place opening (see Figure 5).
Note:

When installing your gas logs into a

manufactured firebox, follow firebox
manufacturer’s instructions for minimum
clearances to combustible materials.

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

INSTALLATION

Continued

NOTICE: Manual control heaters
may be used as a vented prod-
uct. If so, you must always run
heater with chimney flue damper
open. If running heater with
damper open, noncombustible
material above fireplace open-
ing is not needed. Go to Install-
ing Damper Clamp Accessory for
Vented Operation,

page 11.

Minimum Noncombustible Material
Clearances

If Not Using Mantel

Note:

If using a mantel, proceed to If Using Mantel,

page 10. If not using a mantel, follow the informa-
tion below.
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least 1/2
inch thick. With sheet metal, you must have non-
combustible material behind it. Noncombustible
material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you
must install the fireplace hood accessory (24" and
30" models only). See Figure 6, page 10 for mini-
mum clearances.
IMPORTANT:

If you cannot meet these minimum

clearances, you must operate heater with chim-
ney flue damper open. Go to Installing Damper
Clamp Accessory for Vented Operation,
page 11.

Figure 5 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

Example

*