LOCAL CODES

Install and use heater with care. Follow all local
codes. In the absence of local codes, use the latest
edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*
.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note:

Where listed vented decorative logs are re-

quired, thermostat operation is not permitted.

UNPACKING

CAUTION: Do not remove the

data plates from the grate as-
sembly. The data plates contain
important product information.

1. Remove logs and heater base assembly from

carton. Note: Do not pick up heater base as-
sembly by burners. This could damage heater.
Always handle base assembly by grate.

2. Remove all protective packaging applied to

logs and heater for shipment.

3. Check all items for any shipping damage. If

damaged, promptly inform dealer where you
bought heater.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a
chimney. Heat is generated by realistic dancing,
yellow flames. This heater is designed for vent-
free operation with flue damper closed. It has been
tested and approved to ANSI Z21.11.2 standard
for unvented heaters. State and local codes in some
areas prohibit the use of vent-free heaters. This
heater may also be operated as a vented decora-
tive (ANSI Z21.60) product by opening the flue
damper (non-thermostat operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion
Sensing (ODS) safety shutoff system. The ODS/
pilot is a required feature for vent-free room heat-
ers. The ODS/pilot shuts off the heater if there is
not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re-
quires no matches, batteries, or other sources to
light heater.

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall

not be installed in a confined
space or unusually tight con-
struction unless provisions are
provided for adequate combus-
tion and ventilation air. Read
the following instructions to in-
sure proper fresh air for this
and other fuel-burning appli-
ances in your home.

Today’s homes are built more energy efficient than
ever. New materials, increased insulation, and new
construction methods help reduce heat loss in
homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy effi-
cient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.

PROVIDING ADEQUATE
VENTILATION

The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air
for Combustion and Ventilation.
All spaces in homes fall into one of the three fol-
lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help
you classify your space and provide adequate
ventilation.