TROUBLESHOOTING

Note:

All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equip-

ment shutoff valve closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when installed

5. Depleted gas supply (propane/

LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching ther-

mocouple, which allows ther-
mocouple to cool, causing pi-
lot flame to go out. This prob-
lem could be caused by one or
both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep
ignitor cable dry

3. Tighten nut holding piezo igni-

tor to base panel of log set. Nut
is located behind base panel

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down con-

trol knob. Repeat igniting op-
eration until air is removed

5. Contact local propane/LP gas

company

6. Clean ODS/pilot (see Clean-

ing and Maintenance, pages
24 and 25) or replace ODS/
pilot assembly

7. Replace gas regulator

1. Press in control knob fully
2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Fully open equipment shutoff

valve

4. A) Contact local propane/LP

or natural gas company

B) Clean ODS/pilot (see
Cleaning and Maintenance,
pages 24 and 25) or replace
ODS/pilot assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace pilot assembly
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed,
there is no spark at ODS/pilot

When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition

ODS/pilot lights but flame goes
out when control knob is re-
leased