Installation – Desa CGD3018PT/NT User Manual

Page 13

Advertising
background image

www.desatech.com

111160-01C

13

INSTALLATION

Continued

Figure 13 - Attaching Base Assembly to

Fireplace Floor - Dual Burner Model

Masonry
Screw

Mounting
Bracket

Masonry
Screw

Figure 14 - Attaching Base Assembly to

Fireplace Floor - Single Burner Model

Mounting
Bracket

7. Mark screw locations through holes in mount-

ing brackets (see Figure 13 and 14). If install-
ing in a brick-bottom fireplace, mark screw
locations in mortar joint of bricks.

8. Remove heater base from fireplace.
9. Drill holes at marked locations using 3/16"

drill bit.

10. Attach base assembly to fireplace floor using

two masonry screws (in hardware package)
(see Figure 13 or 14).

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.

WARNING: A qualified ser-

vice person must connect
heater to gas supply. Follow all
local codes.

CAUTION: Never connect

heater directly to the propane/
LP supply. This heater requires
an external regulator (not sup-
plied). Install the external regu-
lator between the heater and
propane/LP supply.

WARNING: Never connect

natural gas fireplace to private
(non-utility) gas wells. This gas
is commonly known as well-
head gas.

Installation Items Needed
Before installing heater, make sure you have the
items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certified equipment shutoff valve from your
dealer. See Accessories, page 43.