3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large
particles of dust, dirt, lint, or pet hair with a
soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the in-

jector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4 on
page 24.

Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figure 42). With the
unit off, lightly blow air through the air inlet hole.
You may blow through a drinking straw if com-
pressed air is not available.

CLEANING AND

MAINTENANCE

Continued

Figure 41 - Injector Holder On Outlet

Burner Tube

Burner Tube

Primary Air
Inlet Holes

Injector
Holder

Figure 42 - Pilot Inlet Air Hole

Burner Tube

Pilot Assembly

Pilot Air
Inlet Hole

Ports/Slots

LOGS

• If you remove logs for cleaning, refer to In-

stalling Logs, pages 16 through 19, to properly
replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

MAIN BURNER

Periodically inspect all burner flame holes with
the heater running. All slotted burner flame holes
should be open with yellow flame present. All
round burner flame holes should be open with a
small blue flame present. Some burner flame holes
may become blocked by debris or rust, with no
flame present. If so, turn off heater and let cool.
Remove blockage. Blocked burner flame holes
will create soot.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas supply

may be low

You may feel your gas pressure is too low. If so,
contact your local propane/LP or natural gas sup-
plier.

TECHNICAL SERVICE

You may have further questions about installation,
operation, or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ tech-
nical service web site at

www.desatech.com.

Advertising
This manual is related to the following products: