ST5/10-Si,-Q,-C, -IP Hardware manual

920-0004 Rev. F

6/10/14

Connecting to PLC with Sinking (NPN) Outputs

(Most PLC’s use 24 volt logic)

Using Mechanical Switches at 24 Volts

DRIVE

+12-24V

X2/DIR+

DIR

X2/DIR-

X1/STEP+

STEP

X1/STEP-

PLC

with

Sinking

Outputs

R
R

DRIVE

+

X2/DIR+

X2/DIR-

X1/STEP+

-

X1/STEP-

+24VDC

Power

Supply

2200
2200

direction switch

run/stop switch

(closed=run)