30

ST5/10-Si,-Q,-C, -IP Hardware manual

920-0004 Rev. F

6/10/14

Connecting another Si™ drive to the ST

(When output closes, input goes low).

Connecting an NPN Type Proximity Sensor to an input

(When prox sensor activates, input goes low).

IN/OUT1

X3..X6

XCOM

DRIVE

OUT+

OUT–

12-24

VDC

Power

Supply

-

+

DRIVE

NPN

Proximity

Sensor

X3..X6

XCOM

output

+

12-24

VDC

Power

Supply

-

+

Connecting an Input to a Switch or Relay

DRIVE

switch or relay

(closed=logic low)

X3..X6

XCOM

12-24

VDC

Power

Supply

-

+