Doremi ShowVault / IMB User Manual

Page 24

Advertising
background image

CRT.OM.001087.DRM

Page 24 Version 1.7

Doremi Labs

6.5 Check the Communication with the IMB

Check the Ethernet:

If the test in Section 6.4 passed, then run the command: /doremi/sbin/sbcsetup.out -a
--get-temperature
(this will exercise the communication with the IMB without the need
of a proper synchronization of certificate). Also, this tests path 2 and path 3.

If it succeeds it means that the hardware and network configuration are "OK".

If it fails, it means that the IMB is not connected via Ethernet to the router internally of
the projector.

This is what typically would require a re-seating of the IMB (or modified front plate).

Check the certificate configuration:

Run the command: /doremi/sbin/sbcsetup.out --get-version

If it succeeds, the Showvault and IMB are communication find and there is no problem.

If the command reports a failure with "mismatch key", it means that the certificate in
/doremi/etc/certs/mine is not the one corresponding to the IMB it is connected to.

The easiest is to reboot the ShowVault. The synchronization of the certificate should be
done during reboot.

It might be necessary to remove all the pem files in /doremi/etc/certs/mine before the
reboot.

A more complicated (more complicated to have a technician on the phone to execute)
but quicker way to fix is it: Run the command: /doremi/sbin/sbcsetup.out -a -f --verify -
-force-repair

Again try the command /doremi/sbin/sbcsetup.out --get-version, if it succeeds the
problem is fixed.