Page 25 Version 1.7

Doremi Labs

6.6 How to Generate a Detailed Report

If the issue is still not fixed generate a Detailed Report and send it to Doremi Technical Support
(especially BEFORE replacing the current IMB). Along with the Detailed Report, send the
following information: Site name and number, screen number, S/N of the ShowVault, and
projector version.

6.7 IMB Configuration Script

You can execute the script IMB_Configuration_check.sh which will run the commands
outlined in Section 6.5.

The script will be available in /doremi/bin. If

it’s not, please copy it there.

To run the script: Type: > /doremi/bin/IMB_Configuration_check.sh

The script will run multiple commands. You have to press enter to proceed after each
command.

Below are the details of the script as the technician will see it. In case of a failure, the script will
prompt the technician on the steps needs to be taken and it will exit. The technician needs to
follow the script instructions and run the script until it passes all of them.

Checking the IMB is seen on the PCIexpress

IMB was found on the PCIexpress

Continue (y/n)?

y<enter>

Checking IMB IP configuration

IMB internal IP is OK

Continue (y/n)?

y <enter>

Checking the Projector IP configuration

Inet addr:10.10.1.120 Mask:255.255.255.248

Is this the correct IP addr for the projector (y/n)?

y<enter>

Checking the ethernet connection with projector

The projector ethernet is properly connected

Continue (y/n)?