Setup protocol – NeoPro Borrego+ 8x8 User Manual

Page 22

Advertising
background image

22

DOC42-00027-B Integrator's Guide.doc

Switch all outputs to input 1, set all volumes to 99

Restore the saved configuration once the paging is done

The macro for this sequence is:

[M,S,1]

{[BA,1,0][BL,99,0]}

[M,R,1]

Memory Edit

Memory edit allows the user to modify the contents of a memory slot. To do
this, send the memory edit command then send a group command:

[M,E,n]

{ [ ] [ ] [ ] [ ] }

n is the memory slot to edit

For this code format, note:

These commands will be stored in the memory location, but will not be
executed.

The memory edit function only accepts switch commands, including
volume & tone commands.

The commands can contain a time parameter, as used for audio
transitions.

While memory edit command is active invalid code inside a group
bracket

{ }

will be ignored.

Commands after the closing bracket will be treated as normal
commands.

If no opening bracket is detected right after invoking the memory edit
command, the program will exit the memory edit function without
saving anything to the designated memory location.

Setup Protocol

Setup commands have 3 parameters:

[S,x,n]

S

invokes the Setup function

The table below lists values for

x

and

n:

x

n

Setup function

L

0

Led OFF

Advertising