Installation, Unpacking, Mounting requirements – NeoPro Borrego+ 8x8 User Manual

Page 7: Cat5 installation

Advertising
background image

7

DOC42-00027-B Integrator's Guide.doc

Installation

Unpacking

The NeoPro matrix ships with the following:

1

AC Power cord

1

6 ft. (1.82 m) USB cable

1

6 ft. (1.82 m) RS-232 cable

1

Integrator’s Guide (manual)

1

CD-ROM driver disc

1

Pair of rack mount ears with screws

Optional: NeoPro IR remote control

There is a clear film to protect the front panel. To ensure proper touch panel
response, remove this film before use.

Mounting Requirements

The NeoPro matrix switch has cooling vents on the sides that must not be
covered. Other equipment may be stacked on top of it. It has padded feet, so the
matrix may stacked on top of other equipment without causing damage. For
rack mounting (2U height), remove the padded feet.

CAT5 Installation

!IMPORTANT!

READ BEFORE INSTALLING ANY CABLES

When installing CAT5 cables to the NeoPro matrix or the NeoPro baluns,
remove the AC supply to the unit. The CAT5 circuit supplies 24Vdc from the
matrix and the in-wall baluns have an exposed circuit board that may be
damaged if accidently shorted during mounting.

CAT5 Cable Pin-Outs

!CAUTION!

Before connecting CAT5 cables, make sure the wire pairs are terminated as
shown in Fig.1 and the table below. Do not use any other type of CAT5 balun
with the NeoPro matrix, as they may cause damage to the matrix and the NeoPro
baluns, which is not covered by the NeoPro warranty. The common standards