Xtramus DApps-MPT V1.4 User Manual

Page 31

Advertising
background image


31

E-mail: [email protected]

Website: www.Xtramus.com

XTRAMUS TECHNOLOGIES

®

D. Filter Test

This filter test should filter all packets with the same source MAC address and destination MAC Address.

For this test, test packet sent are all with the same source MAC address and destination MAC address

and the DUT should filter this kind of packet.

Perform filter test on DUT in layer2 with different speeds, mode and various configurations. The following

tasks transmit frames with same DA (destination address) and SA (source address).

PT2-FT-10H,

PT2-FT-10F,

PT2-FT-100H,

PT2-FT-100F,

PT2-FT-1G,

PT2-FT_FULL (Perform Layer 2 Filter Test by two groups with different media type such as 100Mbps

and 1000Mbps for DUT ports with different maximum speeds.)

E. CRC Error Test
CRC Checksum is registered at the end of Ethernet frame.

Perform CRC (Cyclic Redundancy Check) error test on DUT in layer2 with different speeds, mode and

various configurations for the last 4 bytes of CRC to be filtered. For normal DUT, frame with error CRC

should be filtered. The following tasks transmit frames with CRC errors

.

PT2-CRC-10H, (10Mbps, Half Duplex)

PT2-CRC-10F, (10Mbps, Full Duplex)

PT2-CRC-100H, (100Mbps, Half Duplex)

PT2-CRC-100F, (100Mbps, Full Duplex)

PT2-CRC-1G, (1Gbps, Full Duplex)

PT2-CRC-FULL (Perform Layer 2 CRC check test by two groups with different media type such as

100Mbps and 1000Mbps for DUT ports with different maximum speeds.)

Advertising
This manual is related to the following products: