AMETEK XBT Series User Manual
Page 43

Remote Interface Protocol and Package Mode
STAT:ERROR?
How to read voltage setting DAC value:
STATUS:CVP?
==> read CVP DAC value
How to read current setting DAC value:
STATUS:CCP?
==> read CCP DAC value
How to read voltage DAC value:
STATUS:MONV?
==> read MONV DAC value
How to read current DAC value:
STATUS:MONI?
==> read MONI DAC value
How to set all channels to synchronously output:
OUT:ALL 1
==> tri-channel output is ON
OUT:ALL OFF
==> tri-channel output is OFF
How to set up timer:
TIMER 00:10:00
==> set up the timer to run for 10 minute
TIM 99:59:59
==> set up timer to run 99 hours 59 minutes 59
seconds and then stop
How to start timer:
TIMER ON
TIM ON
How to close timer:
TIMER OFF
TIM OFF
How to read timer parameter:
TIMER?
TIM?
M370187-01 Rev J