System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

40

In case of OEM multi records, Artesyn HPI-B always assumes
DataType=SAHPI_TL_TYPE_BINARY and Language=SAHPI_LANG_UNDEF for the field on
which the API is being called.

Limited saHpiResourceResetStateSet() call
Artesyn HPI-B does not support Reset Action SAHPI_RESET_ASSERT.

Unsupported saHpiParamControl() call
Artesyn HPI-B does not support saHpiParamControl().

Unsupported resource event log
Artesyn HPI-B does not support resource event logs.

Unsupported Unicode character set
Artesyn HPI-B does not support the Unicode character set.

Unsupported annunciator functionality
Artesyn HPI-B does not support annunciator functionality. Our platforms do not have
these features.

Unsupported SaHpiIdrFieldAdd() and SaHpiIdrFieldAddById() call
Artesyn HPI-B does not allow adding field in an inventory area with the above APIs.
To add a new field, add a new OEM area and use the second field of the area.

Optional APIs saHpiInitialize() and saHpiFinalize() are not supported.

FUMI explicit banks are not supported, only logical bank is used for FUMI APIs.

APIs saHpiFumiBackupStart(), saHpiFumiBankCopyStart(),
saHpiBankBootOrderstart()

, saHpiTargetVerifyStart(), and

saHpiFumiRollbackstart()

are not supported.

FUMI APIs saHpiFumiUpgradeCancel() and saHpiFumiCleanup() cannot
preempt the image activation process as it can result in image corruption. We do not stop
the activation process once it is started.