Table 4-42, Parameters of cooling system, Using hpi-b – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual

Page 79

Advertising
background image

Using HPI-B

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

79

Reboot the Shelf Manager or restart the HPI daemon with sv_stop and sv_start
commands in order to activate the modified configuration. Assure that the active Shelf
Manager works with the modified configuration file.

Table 4-42 Parameters of Cooling System

Parameter Name

Default Value

Description

OPENHPI_LOG_DEBUG_FACILITIES

“”

"ipmicooling" enables logging. It enables
the shelf manager to log the cooling
related information into files
/var/log/bbs-hpib0X.log

where

X

can be in the range of 0 to

OPENHPI_LOGFILE_MAX

as

mentioned in the /etc/bbs-
hpib/bbs-hpib.conf

configuration

file.

Cooling_DeactOnUpperNonRecov

erTemp

<valid only for C2000 R3.0 systems>

“1”

Enables the function to power off all
blades and drop fan speed after
receiving upper non recoverable (UNR)
thermal events from two different
resources in the C2000 R3.0 shelf.

Cooling_FanMinimumLevel

“12|15”

Default fan speed in %.
12 - default value for C2000 R3.0 shelfs.
15 - default value for the other shelfs.

Cooling_InletOutletLowerTemp

erature

“20”

Lower temperature point for inlet/outlet
control

Cooling_InletOutletUpperTemp

erature

“40”

Upper temperature point

Cooling_InletOutletLowerSetP

oint

“10”

Set point at upper temperature

Cooling_InletOutletUpperSetP

oint

“25”

Set point at lower temperature Range 25
to 15, most effect at 15. Influences the
difference between in- and outlet
temperature.

Cooling_InltOutltMinimumSens

orTemperature

“18”

Below this inlet temperature the
inlet/outlet related control is disabled