Using hpi-b – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual
Page 96
 
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
96
This invokes the FUMI call saHpiFumiTargetVerify(). This call is intended to be invoked 
after the upgrade has finished. It verifies the new, updated image at the target memory 
matches with the source image. Refer to the FUMI specification for details. 
-c
This invokes the FUMI call saHpiFumiUpgradeCancel().
This command is currently not supported.
-V
This invokes the version number of the hpifumi command itself.
-h
This displays help information, which includes parameter description and overall functionality 
description. 
-n COMPONENT_ID
The component identifier of the component for which the information is required.
-Z Rollback_disable
A Boolean value representing the value you want to set for the auto rollback status.
-I
Spec information for the underlying IPMC. Invokes the API saHpiSpecInfoGet().
-D
This provides service impact information while in case an IPMC is upgraded, there will be 
impact on the Service provided by IPMC or not. Invokes the API 
saHpiFumiServiceImpactGet()
.
-C
Source component Information, after the upgrade image has been validated you can view the 
source component information provided by image. Invokes the API 
saHpiFumiSourceComponentInfoGet()
.