Using HPI-B

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

98

Example

Updating the IPMC Firmware of HPM.1 Compliant Blade via the hpifumi Example
Tool

In order to upgrade the IPMC firmware of HPM.1 compliant blade, proceed as follows.

1. Copy the new firmware image file to a directory on the blade where the hpifumi

example application runs.

2. Identify the FUMI object which represents the IPMC of the blade. This can be

achieved by entering hpifumi without any parameters. All available FUMI objects
will then be displayed in a way similar to the following example output.

resource: 65 ATCA-MF106:

{ADVANCEDTCA_CHASSIS,6}{SHELF_MANAGER_SLOT,1}{SHELF_MANAGER,1}

Fumi 0

IdString : IPMC

AccessProt : SAHPI_FUMI_PROT_LOCAL

Capability :

NumBanks : 1

Oem : 0x00100000

resource: 70 ATCA-MF106:

{ADVANCEDTCA_CHASSIS,6}{SHELF_MANAGER_SLOT,2}{SHELF_MANAGER,2}

Fumi 0

IdString : IPMC

AccessProt : SAHPI_FUMI_PROT_LOCAL

Capability :

NumBanks : 1

Oem : 0x00120000