Front panel overview, Control keys, Power switch/circuit breaker – Dukane Ultrasonic Hand Held System iQ Series User Manual

Page 23

Advertising
background image

Page  17

Section 4 – Controls and Connections

Dukane Manual Part No. 403-577-01

Figure 4-1 Front Panel

Front Panel Overview

This section gives an overview of the front panel functions:
powering the generator on/off; monitoring the process with
the display; and, programming with the control keys.

Control Keys

The control keys shown in Figure 4-1 and described
below, are used to display information, and to program
the generator.

INFO

Press this key to get system information or to modify the
hardware settings.

System Information -

Identifies the current

version of system software.

Hardware Settings -

Select features that can be

turned on or off including the Audible Alarm or Fault
Latching options.

SETUP

Use the SETUP key to Load, Store, or Delete as many as
eight setups.

Power
Switch

Control Keys

LCD Display

Power Switch/Circuit Breaker

The power switch/circuit breaker has a rocker-style actua-
tor switch that will activate or deactivate the AC power
to the system. The power ON position is marked with the
internationally recognized I symbol, the power OFF posi-
tion is marked with the 0 symbol. This power switch also
integrates an appropriately sized over-current protection
circuit breaker function in the generator.
If an over-current condition trips the circuit breaker, it will
automatically switch to the OFF position. If the overload
current that caused the circuit breaker to trip is due to a
transient condition, the circuit breaker can be reset by
switching the actuator back to the ON position.

CAUTION

If when resetting the circuit

breaker afer it has tripped, it

immediately trips again, there

is likely an internal system

malfunction, and the generator

will need service. Do NOT re-

peatedly try to reset the circuit

breaker. If it trips, this will only

cause more damage to the

generator.

  

Continued