Section 7 – Troubleshooting

Page  4

Dukane Manual Part No. 403-577-01

Generator Fault Status Screens - Manual Mode

Status Text Displayed

System Status or Fault Explanation

An Average Overload fault tripped.
Output power exceeded rated wattage.
Lower the welding pressure or amplitude.
Fault will reset when next weld cycle starts.

A Positive Peak Overload fault tripped.
Peak IGBT transistor current exceeded.
Caused by a severe frequency mis-match.
Fault will reset when next weld cycle starts.

Resonant frequency lock not found, or lost.
Check for a defective stack component.
Check for stack coupling to the fixture.
Fault will reset when next weld cycle starts.

System Overtemperature fault detected.
Fault will reset when system cools down.

Internal communications error.
Turn generator power off and back on.
Call Dukane service if the fault persists.

Pop-up Fault Status Screens

Table 7- I

Pop-Up Fault Status Screens - Manual Mode

Generator Fault

Average Overload

Generator Fault

Peak Overload

Generator Fault

Frequency Lock Lost

Generator Fault

Over Temperature

  

Continued

Generator Fault

Cycle Power