iQ Series,

Ultrasonic Hand Held Systems User’s Manual

Dukane Manual Part No. 403-577-01

Process Fault Status Screens - Time and Energy Modes

Status Text Displayed

System Status or Fault Explanation

Latch On Fault ENABLED

Latch On Fault DISABLED

Set Weld Time Not Reached, or
Set Weld Energy Not Reached - appears if the
weld ends before the set time or energy is reached
(respectively) due to operator error, or
because the weld was intentionally aborted.

Peak Overload, Average Overload, Frequency Lock 
Lost, Input Undervoltage, 
or Over Temperature is
displayed in place of Set Weld Time not Reached,
or Set Weld Energy not Reached, if the weld ends
before the set time or energy is reached due to a
process or generator fault.

Process Fault

Set Weld

Time Not Reached

Enter Clears Fault

Process Fault

Set Weld

Energy Not Reached

Enter Clears Fault

Process Fault

Peak Overload

Time Not Reached

Enter Clears Fault

Process Fault

Frequency Lock Lost

Energy Not Reached

Enter Clears Fault

Process Fault

Input Undervoltage

Energy Not Reached

Enter Clears Fault

Process Fault

Set Weld

Time Not Reached

Process Fault

Set Weld

Energy Not Reached

Process Fault

Average Overload

Time Not Reached

Process Fault

Over Temperature

Energy Not Reached

Table 7-II

Pop-Up Fault Status Screens - Time and Energy Modes