Section 6 – Probes and Probe Stacks

Dukane Manual Part No. 403-577-01

6. Thread the components together and tighten to the

following torque specifications using only the correct
size wrenches. Use spanner wrenches on components
with spanner wrench holes or an open end wrench on
components with wrench flats. See Figure 6–5 for the
correct procedure. Refer to Table 6-III for torque unit
conversions. Be careful not to overtighten.

Table 6-III Horn/Booster Torque Unit Conversions

NOTE

Horn and booster torque specifications
are higher than stud torque specs. Be
sure to tighten the horn or booster joints
to the higher torque limits.
Do not tighten the studs to these higher
ratings as it may induce unnecessary
stress in the assembly.

In-lb Ft-lb N-m

kHz

540

45

61

15 kHz stack

420

35

47.5 20 kHz stack

216

18

24.4 30 kHz stack

216

18

24.4 40 kHz stack