LCD Display Overview

There are two basic kinds of screen displays:

Operate

screens, and

In Cycle

screens.

Figure 4-5 Example of an In Cycle Screen

IN CYCLE

Frequency: 40087 Hz

Power: 25 W

# 2

Status Indication

Stack Frequency

Power Draw

Power Bar Graph %

Figure 4-4 Example of an Operate Screen

Weld Mode -
Manual, Time, or
Energy

Manual Weld

Weld Time 0.500 S

Weld Energy 18 J

# 2

*

Data from
last weld
cycle.

Setup
number.

Asterisk indicates setup
is modified but not
stored in memory.

An Operate screen tells the operator
what happened in the last weld cycle.

An In Cycle screen activates when the probe activation
switch (trigger) is pressed.