2-14

Seam parameter 25 = 01 cm

When defining SP 23 (duration final roller) = 00 and NSP 23 = 00 sec., the
final roller won’t get active; the main clamp remains closed and drives without
clamp pressure to the insertion position.

Seam parameter 25 = 20 cm

Pic up parts with the main clamp until 20 cm before the insertion position.

3.4

Seam images

3.4.1

Sewing with catch

3.4.2

Sewing with stitch condensation

3.4.3

Sewing with stowing