2-26

02

Main clamp laterally

Y02

2

X35 pin 14

56

Pocket welt turner device bed slide

Y56

56

X26 Pin 22

57

Pocket welt t. device outside seam st. Y57

57

X25 Pin 12

58

Pocket welt t. device outside seam e. Y58

58

X25 Pin 11

59

Pocket welt turner device up

Y59

59

X26 Pin 21

31

Zipperfinger move

Y60

60

X26 Pin 23

32

Ziipperfinger up/down

Y61

X26 Pin 24

20

Needle strip big

Y08

08/08.1

X26 Pin 25

5.5.2

Diagnostics

1. Press the P-key.

2. Press the F6-key.

3. Press the F3-key.

Here you can choose from six different sub-menus, with which you are able
to check system components individually.

5.5.2.1

Service Test

ATTENTION

These tests may only be executed by service technicians of the company
Beisler. The complete loss of all data can easily occur due to false
operations.

5.5.2.2

Sewing motor

1. Press the P-key.

2. Press the F6-key.

3. Press the F3-key.

4. Press the F2-key.

Here, four tests for the sewing motor are contained. Select the desired test
by pressing the corresponding F-key:

F1

Select sewing motor

Here the actual value is compared with the must value of revs of the sewing
motor. After opening the test, you can enter the desired revs using the
number keys.

ATTENTION

The insertion station must be swung out and all threats and bobbins must be
removed from the sewing head before the test can be executed. Beisler
sewing heads may only be run with revs up to 2500 Rpm.

Enter the desired revs of the motor and press the ENT-key. The sewing head
starts and the measured actual value is displayed.

Press the P-key to terminate the test.