2adjustments at the insertion station – Beisler 100-58 User Manual

Page 63

Advertising
background image

3-13

2.1

Folder height

Select output 24/25 in the machine control.

The distance (A) between sliding plate and folder sole
must be adjusted to the used sewing material. The ba-
sic setting is 2 mm.

If the folder is set too deep, the material will be blocked.
If it is too high, the folding slides cannot fold the sewing
material.

Loosen the nut (1) and turn the allen screw (2) in or out.
Tighten the fixing screw (1) again.

After changing the folder height, the position of the in-
itiator at the insertion plate should be checked (see sec-
tion 2.2).

2

Adjustments at the insertion station

2.2

Initiator at the insertion plate

When the folder is lowered completely, this initiator will
be switched and triggers the closing of the folding slides
(if activated in the program). If the initiator isn’t set cor-
rectly, the folding slides come too early or not at all.

Loosen the fixing screws (1) to adjust the initiator and
move it correspondingly. Tighten both fixing screws again.

2.3

Folder free play

<power off> <release pressure>

The folder should not have any free play in folding posi-
tion (see picture at section 2.1).

To adjust the free play, loosen the fixing screws at the
stop bar and push it towards the bearing. Tighten both
screws again.

2.4

Folder parallel to main clamp

<power off> <release pressure>

Loosen the allen key (4) a little and adjust the folder par-
allel to the main clamp.

Tighten the allen key in this position.

Advertising