9 remote music mute - fire alarm interface, 10 technical specifications – Cloud Electronics CX462 User Manual

Page 18

Advertising
background image

CX462 Audio System Controller

Setup And Installation Guide

CLOUD ELECTRONICS LIMITED

9 Remote Music Mute - Fire Alarm interface

In certain installations, such as licensed premises or retail outlets within a shopping mall, there may be
a local authority or fire service requirement to mute the music signals via a fire alarm control panel in
an alarm condition. The CX462 provides a facility to mute the music signals only, by using a fully
isolated pair of contacts. This is usually a relay mounted close to the CX462, which is powered by the
fire alarm control panel. The relay can either be closed or opened in an alarm condition, but the
internal jumper J13 MUST be set to the corresponding position:

M N/C: Alarm condition when the relay opens.
M N/O: Alarm condition when the relay closes.

When setting the jumper(s) please ensure that you:

• Remove the mains cable from the rear of the product before removing the top panel.
• Only reassemble the unit using screws identical to the original parts.

10 Technical Specifications

Line Inputs

Microphone Inputs

12

V3 280904

Frequency Response

20Hz-20kHz

+0, -0.5dB

Distortion

<0.03%

80kHz Bandwidth

Sensitivity

100mV (-17.8dBu) to 1.5V (+5.7dBu)

Input Gain Control

24dB range

Input Impedance

48kΩ

Headroom

>20dB

Noise

-91dB rms

22kHz Bandwidth (0dB gain)

Equalisation

HF: ±10dB/10kHz, LF: ±10dB/50Hz

Frequency Response

-3dB@ 30Hz (without filter)

20kHz -0.5dB, +0dB

-3dB@ 150Hz (with filter)

Distortion

<0.05%

20kHz Bandwidth

Gain Range

0dB-60dB

Input Impedance

>2kΩ(balanced)

Common mode rejection

>70dB 1kHz Typical

Headroom

>20dB

Noise

-128dB rms EIN

22kHz Bandwidth

Equalisation

HF: ±10dB/5kHz LF: ±10dB/150Hz

Advertising