Interface checkout, 1 interface checkout – Comtech EF Data SNM-1002 User Manual
Page 110
Advertising

SNM-1002 LinkSync
Modem
Revision 2
Maintenance
MN/SNM1002.OM
5–2
5.1.1 Interface
Checkout
Use the following procedure and the test setup in Figure 5-1 to inspect the interface.
Figure 5-1. Fault Isolation Test Setup
1. Connect a BER test set to the appropriate modem data connector as shown in
Figure 5-1. Refer to Chapter 2 for external modem connections.
2. Set up the modem for baseband loopback operation by using the directions
provided in section A.3.3. The modem will run error free.
3. Change the modem from baseband loopback to interface loopback operation by
using the directions provided in section A.3.3. The modem will run error free.