Comtech EF Data SNM-1002 User Manual
Page 61

SNM-1002 LinkSync
Modem
Revision 2
Operation
MN/SNM1002.OM
3–21
FUNCTION SELECT
MONITOR
3.4.2.1 MONITOR:RAW
BER
RAW BER
NO DATA
Displays the current BER or “No Data” (if carrier is not locked).
Range: < m.m E-e to > m.m E-e.
Note: Low limit is based on performance. High limit is based on data/code rate.
3.4.2.2 MONITOR:CORRECTED
BER
CORRECTED BER
NO DATA
Displays the current corrected BER or “No Data” (if carrier is not locked).
Range: 1.0 E-3 to 1.0 E-12.
Note: Low limit is based on performance. High limit is 1.0 E-12.
3.4.2.3 MONITOR:EB/NO
EB/NO
16.0
Displays the current Eb/N0 or “No Data” (if carrier is not locked).
Range: 2.0 to 16.0 dB.
Note: Low limit is based on the data rate. High limit is 16.0 dB.
3.4.2.4 MONITOR:RECEIVE
SIGNAL