Command/response pairs – Comtech EF Data XPA-200 User Manual
Page 60

XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-8
5.8 COMMAND/RESPONSE PAIRS
5.8.1 Utility Commands
5.8.1.1 Time
Set Time:
<DEV/TIM_hh:mm:ss'cr'
hh = Hour*
Confirmation:
>DEV/TIM_hh:mm:ss'cr''lf']
mm = Minutes
ss = Seconds
Retrieve Time: <DEV/TIM_'cr'
Confirmation:
>DEV/TIM_hh:mm:ss'cr''lf']
* Note: 24 hour military time is used.
5.8.1.2 Date
Set Date:
<DEV/DAT_mm/dd/yy'cr'
mm = Month
Confirmation:
>DEV/DAT_mm/dd/yy'cr'lf']
dd = Day
yy = Year
Retrieve Date: <DEV/DAT_'cr'
Confirmation:
>DEV/DAT_mm/dd/yy'cr''lf']
5.8.1.3 Physical Address
The default Physical Address from is 1.
Set Physical Address: <DEV/SPA_xxx'cr'
xxx = 1 to 255
Confirmation:
>DEV/SPA_xxx'cr''lf']
Retrieve Phys. Addr: <DEV/SPA_'cr'
Confirmation:
>DEV/SPA_xxx'cr''lf']
5.8.1.4 Baud Rate
The default baud rate is 9600.
Set Baud Rate:
<DEV/SBR_xxxx'cr'
xxxx = 300,
Confirmation:
>DEV/SBR_xxxx'cr''lf'] 1200, 2400,
4800 or 9600
Retrieve Baud Rate: <DEV/SBR_xxxx'cr'
Confirmation:
>DEV/SBR_xxxx'cr''lf']