Error processing – Comtech EF Data XPA-200 User Manual
Page 69

XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-17
5.8.4 Stored Alarm
The 100 alarms are date/time stamped and stored in memory as
they occur. The alarm entry is also updated with its date/time
of clearance. The entry remains in memory until it is removed by
command.
5.8.4.1 Total Stored Alarms
This command retrieves the total number of stored alarms and
the time and date of the most recent alarm.
Retrieve Total Alarms:
<DEV/TSA_'cr'
Confirmation:
>DEV/TSA_TOTAL:nnn'cr'
LAST:hh:mm:ss mm/dd/yy'cr''lf']
5.8.4.2 Clear All Stored Alarms
Clear Alarms:
<DEV/CAA_YES'cr'
Confirmation:
>DEV/CAA_CLEARED'cr''lf']
5.8.4.3 List All Alarms
List All Alarms: <DEV/LAA_'cr'
Confirmation:
>DEV/LAA_'cr'
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'
"
"
"
"
"
"
"
"
xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr''lf']
Where:
xxx = stored fault number
yyyyyyyyyyy = fault description
hh:mm:ss = fault time
mm/dd/yy = fault date
5.9 ERROR PROCESSING
5.9.1 General Errors
The following Error Responses may be generated by any
command instead of a confirmation: