Comtech EF Data XPA-200 User Manual
Page 61

XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-9
5.8.1.5 Parity Bit
The default parity is even.
Set Parity Bit:
<DEV/SPB_xxxx'cr'
xxxx = ODD
Confirmation:
>DEV/SPB_xxxx'cr''lf']
or EVEN
Retrieve Parity Bit:
<DEV/SPB_'cr'
Confirmation:
>DEV/SPB_xxxx'cr''lf']
5.8.1.6 LCD Contrast
The default is 15.
Set Contrast:
<DEV/CON_xx'cr'
xx = 0 to 30
Confirmation:
>DEV/CON_xx'cr''lf']
Retrieve Contrast:
<DEV/CON_'cr'
Confirmation:
>DEV/CON_xx'cr''lf']
5.8.1.7 LCD Brightness
The default is 15.
Set Brightness:
<DEV/LCD_xx'cr'
xx = 0 to 30
Confirmation:
>DEV/LCD_xx'cr''lf']
Retrieve Brightness:
<DEV/LCD_'cr'
Confirmation:
>DEV/LCD_xx'cr''lf']
5.8.1.8 Lamp Test
The default is off.
Test Lamps:
<DEV/LAM_xxx'cr'
xxx = ON or OFF
Confirmation:
>DEV/LAM_xxx'cr''lf']
Lamp Test Status:
<DEV/LAM_'cr'
Confirmation:
>DEV/LAM_xxx'cr''lf']