Comtech EF Data XPA-200 User Manual
Page 64

XPA200-7984-I-OPT1, X-Band SSPA
Remote Control
Remote Control
XPA200-7984-I-OPT1, Rev.2
5-12
Set Fault Recovery: <DEV/AFR_xxx'cr'
xxx = ON or 0FF
Confirmation:
>DEV/AFR_xxx'cr''lf']
Retrieve Status:
<DEV/AFR_'cr'
Confirmation:
>DEV/AFR_xxx'cr''lf']
5.8.3 Status Commands
Status commands retrieve configuration, maintenance and
alarm status in summary form.
5.8.3.1 Configuration Status
Configuration Status:
<DEV/RCS_'cr'
Confirmation:
>DEV/RCS_'cr'
ATT_yy.yy'cr'
Attenuator
AMP_nnn’cr’
Amplifier - ON/OFF
TX_nnn'cr'
Transmit - ON/OFF
ONL_nnn'cr'
Online - ON/OFF
AFR_nnn'cr'
Auto Flt Recovery-ON/OFF
5.8.3.2 Maintenance Status
Maintenance Status:
<DEV/RMS_'cr'
Confirmation:
>DEV/RMS_'cr'
V+28_xx.x'cr'
+28 VDC Supply
V+12_xx.x'cr'
+12 VDC Supply
V-12_xx.x'cr'
-12 VDC Supply
V +5_x.x'cr'
+5 VDC Supply
V -5_x.x'cr'
-5 VDC Supply
V+10_1_xx.x'cr'
10 VDC Supply #1
V+10_2_xx.x'cr'
10 VDC Supply #2
TEMP_xx'cr'
Temperature
FPWR_xx.x'cr’
RF Forward Power (dBm)
RPWR_xx.x'cr''lf']
RF Reflected Power (dBm)