Flowserve Worthington WXB User Manual

Page 10

Advertising
background image

WXB USER INSTRUCTIONS ENGLISH - 07/14

Page 10 of 51










Power B [HP]

Power [kW]

dB(A) Value

63

125

250

500

1 K

2 K

4 K

8 K

53.7

40

77

67

71

71

69

69

69

67

62

70

52

78

68

72

72

70

70

70

68

63

91.2

68

79

69

73

73

71

71

71

69

64

119.4

89

80

70

74

74

72

72

72

70

65

157

117

81

71

75

75

73

73

73

71

66

206.7

154

82

72

76

76

74

74

74

72

67

269.7

201

83

73

77

77

75

75

75

73

68

354.3

264

84

74

78

78

76

76

76

74

69

464.3

346

85

75

79

79

77

77

77

75

70

609.3

454

86

76

80

80

78

78

78

76

71

798.5

595

87

77

81

81

79

79

79

77

72

1046.8

780

88

78

82

82

80

80

80

78

73

1372.9

1023

89

79

83

83

81

81

81

79

74

Sound pressure readings are for information only and are not subject to guarantee by Flowserve/IDP.

Decibel readings do not include driver or system noise.

Pump tested at 100% of the best efficiency point at max.impeller diameter with water.

dB correction for combining noises (pump+motor)

Add to the higher level to obtain

the combined noise level,dB

Note :

1) The values showed are measured at a distance of 1 mt. (horizontally) from major pump

surfaces and 1.5 mt. above the floor.

2) The values shown are expressed in dB (A)

3) For Noise Test Procedure refer to Works Standard L-109

4) The values shown have been derived from actual noise-test data and are based on the following conditions:

-

Equipment is located in a free field above a reflecting plane in which the reductionin noise level

in all directions is 6db in each octave band for each doubling of distance.

-

Background noise is 10dB minimum below all noise levels in each octave band.

-

The values shown are at a distance of 1 meter (horizontally) from the major pump surface and

1,5 meters above the floor, using a standard pressure reference of 0,00002 newton per square meter.

-

Overall noise level, dB(A) is determined at points of maximum noise level and the values of all

mid-band frequences are basis A scale readings.

5) Above values are given for 2950 RPM.

When the required condition flow is outside the range of 75 to 125% BEP, a part load correction (PLC) must be

added to the noise level as follows:

Percent of BEP @ required

impeller diameter

PLC

in dB

74 to 62 or 126 to 136

+1

61 to 50 or 137 to 150

+2

49 to 38

+3

37 to 25

+4

1

0.5

0

3

2.5

2

1.5

levels to be combined, dB

Difference between two

Octave MID BAND frequency [Hz]

0

1

2

4

6

9

10

Advertising