Flowserve Worthington WXB User Manual

Page 47

Advertising
background image

WXB USER INSTRUCTIONS ENGLISH - 07/14

Page 47 of 51

FAULT SYMPTOM

Pump overheats and seizes

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Bearings have short life

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Pump vibrates or is noisy

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Mechanical seal has short life

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Mechanical seal leaks excessively

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Pump requires excessive power

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Pump loses prime after starting

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Insufficient pressure developed

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Insufficient capacity delivered

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

Pump does not deliver liquid

⇓

⇓

⇓

⇓

⇓

⇓

⇓

⇓

PROBABLE CAUSES

POSSIBLE REMEDIES

Incorrect type of mechanical seal for operating

conditions.

Consult Flowserve

Shaft running off centre because of worn
bearings or misalignment.

Check misalignment and correct if necessary.
If alignment satisfactotry check bearings for
excessive wear

Impeller out of balance resulting in vibration.

Check and consult Flowserve

Abrasive solids in liquid pumped.

Check and consult Flowserve

Mechanical seal was run dry.

Check mechanical seal condition and source
of dry running and repair

Internal misalignment due to improper repairs

causing impeller to rub.

Check method of assembly, possible damage
or state of cleanliness during assembly

Excessive thrust caused by a mechanical

failure inside the pump.

Check wear condition of Impeller, its
clearances and liquid passages

Excessive grease in ball bearings.

Check method of regreasing

Lack of lubrication for bearings.

Check hours run since last change of
lubricant, the schedule and its basis

Improper installation of bearings

Check method of assembly, possible damage
or state of cleanliness during assembly and
type of bearing used

Damaged bearings due to contamination.

Check contamination source and replace
damaged bearings

C. ELECTRICAL TROUBLES

Wrong direction of rotation.

Reverse 2 phases on motor terminal box

Motor running too slow,

Check motor terminal box connections

Advertising
This manual is related to the following products: