8.2 Changing of mechanical seal

1) Completely drain the pump by using the drain

connection. By pumping explosive or toxic media,
flush the system with Nitrogen.

2) Secure the mechanical seal by putting the

mounting plates into the groove of the shaft
sleeve. Loose the grub screws, and disconnect
the seal piping.

Drain the seal system, if

applicable.

3) For disassembly refer to section 6.7.2, 6.7.3,

Dismantling of the line bearing side, Dismantling
of the thrust bearing side.

4) For assembly refer to section 6.9.3, 6.9.4,

Assembly of the thrust bearing side, Assembly of
the line bearing side.