4 recommended spares – Flowserve Worthington WXB User Manual

Page 29

Advertising
background image

WXB USER INSTRUCTIONS ENGLISH - 07/14

Page 29 of 51

To ensure continuous satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve.
Any change to the original design specification
(modification or use of a non-standard parts) will
invalidate the pump’s safety certification.

6.3.2 Storage of spares

Spares should be stored in a clean dry area away from
vibration. Inspection and retreatment of metallic
surfaces (if necessary) with preservative is
recommended at a 6 monthly interval.

















6.4 Recommended spares

Spares Recommended

Part

Start up

Normal Maintenance

No.of identical pumps

1 - 3

4 - 6

7+

1 - 3

4 - 6

7 - 9

10+

Case

1

Head (case cover and stuffing box)

1

Bearing housing

1

Shaft (w/key)

1

1

2

1

Impeller

1

1

2

3

Wear rings (set)

1

1

1

1

1

2

3

Bearings complete (antifriction,radial)

1

2

3

1

2

3

3

Bearings complete (antifriction,thrust)

1

2

3

1

2

3

3

Mechanical seal complete (Cartridge)

1

2

3

1

2

3

3

Shaft sleeve and interstage bush (set)

1

2

3

1

2

3

3

Gaskets, O-rings (set)

1

2

3

1

2

3

3

Balance drum and drum head (set)

1

1

1

1

1

2

3