Flowserve TB-MAG INNOMAG User Manual

Page 7

Advertising
background image

INNOMAG® TB-

MAG™ ASME and ISO SEALLESS ENGLISH 26999988 06-14

Page 7 of 44

Excessive amounts of dust collected on the

pump housing may lead to an increase in surface
temperature, possibly exceeding temperature limits.
May require regular cleaning.

Always have this service manual available during any
installation or maintenance.

1.6.4 Products used in potentially explosive
atmospheres

Measures are required to:

Avoid excess temperature

Prevent build up of explosive mixtures

Prevent the generation of sparks

Prevent leakages

Maintain the pump to avoid hazard


The following instructions for pumps and pump units
when installed in potentially explosive atmospheres
must be followed to help ensure explosion protection.
For ATEX, both electrical and non-electrical equipment
must meet the requirements of European Directive
2014/34/EU (previously 94/9/EC which remains valid
until April 20

th

2016 during the transition). Always

observe the regional legal Ex requirements eg Ex
electrical items outside the EU may be required certified
to other than ATEX eg IECEx, UL.

1.6.4.1 Scope of compliance

Use equipment only in the zone for which it is

appropriate. Always check that the driver and pump
equipment are suitably rated and/or certified for the
classification of the specific atmosphere in which they
are to be installed.

Where Flowserve has supplied only the bare shaft
pump, the Ex rating applies only to the pump. The
party responsible for assembling the ATEX pump set
shall select the coupling, driver and any additional
equipment, with the necessary CE Certificate/
Declaration of Conformity establishing it is suitable for
the area in which it is to be installed.

The output from a variable frequency drive (VFD) can
cause additional heating effects in the motor and so,
for pumps sets with a VFD, the ATEX Certification for
the motor must state that it is covers the situation
where electrical supply is from the VFD. This
particular requirement still applies even if the VFD is
in a safe area.

1.6.4.2 Marking
An example of ATEX equipment marking is shown
below. The actual classification of the pump will be
engraved on the nameplate.

II 2 GD c IIC 135 ºC (T4)

Equipment Group
I = Mining
II = Non-mining

Category
2 or M2 = high level protection
3 = normal level of protection

Gas and/or dust
G = Gas
D = Dust

c = Constructional safety

(in accordance with EN13463-5)

Gas Group
IIA

– Propane (typical)

IIB

– Ethylene (typical)

IIC

– Hydrogen (typical)

Maximum surface temperature (Temperature Class)
(see section 1.6.4.3.)

1.6.4.3 Avoiding excessive surface
temperatures

ENSURE THE EQUIPMENT TEMPERATURE

CLASS IS SUITABLE FOR THE HAZARD ZONE

Pumps have a temperature class as stated in the
ATEX Ex rating on the nameplate. These are based
on a maximum ambient of 40 ºC (104 ºF); refer to
Flowserve for higher ambient temperatures.

The surface temperature on the pump is influenced
by the temperature of the liquid handled. The
maximum permissible liquid temperature depends on
the ATEX temperature class and must not exceed the
values in the table that follows.

Maximum permitted liquid temperature for pumps

Temperature class

to EN13463-1

Maximum surface

temperature permitted

Temperature limit of

liquid handled

T6
T5
T4
T3
T2
T1

85 °C (185 °F)

100 °C (212 °F)
135 °C (275 °F)
200 °C (392 °F)
300 °C (572 °F)
450 °C (842 °F)

65 °C (149 °F) *
80 °C (176 °F) *

115 °C (239 °F) *
180 °C (356 °F) *
275 °C (527 °F) *
400 °C (752 °F) *

* The table only takes the ATEX temperature class into consideration. Pump
design or material, as well as component design or material, may further
limit the maximum working temperature of the liquid.