PHL USER INSTRUCTIONS ENGLISH 00079593

– 10/10

Page 25 of 31

[6570.3] do not protrude above the surface of the
throat bush and the casing cover.

 Tap screw thread into the 3 holes and remove the

metal chips.

 Mount the set screws.

 Fix the set screws using a centre point.

6.9.6

Fitting the impeller wearing rings


The procedure specified below is to be followed

with regard to the impeller wearing rings [2300.1 & 2]
on one or both sides of the impeller.

 Clean the mounting surfaces of the impeller

wearing ring and the impeller.

Use the appropriate personal

protection equipment when heating and positio-
ning the impeller wearing ring.

 Heat the impeller wearing ring to a temperature of

120 to 150

C. Take care if the impeller wearing

ring has a sprayed-on layer of chrome as this may
break away if heating or cooling is carried out
quickly.

 Push the impeller wearing ring right over the

impeller and let the whole assembly cool down.

 Tap screw thread into the 3 holes and remove the

metal chips.

 Mount the set screws [6570.2].

 Fix the set screws using a centre point.

6.9.7

Fitting the case wearing rings


The procedure specified below is to be followed with
regard to the installation of the case wearing ring
[1500.1] in the diffuser. The same procedure can be
followed when installing the case wearing ring in the
casing cover. Read casing cover instead of diffuser.

 Clean the mounting surfaces of the case wearing

ring [1500.1 & 2], the diffuser gland and the pump
casing.

Use the correct personal protection

equipment when cooling and positioning the case
wearing ring.

 Cool the case wearing ring using liquid nitrogen.

 Lower the case wearing ring vertically in the

diffuser and wait until the case wearing ring is
tight.

 Drill 3 holes at 120

intervals in the partition

between the case wearing ring and diffuser. Drill
the holes to a depth such that the set screws

[6570.2] do not protrude above the surface of
the case wearing ring and the diffuser plate.

 Tap screw thread into the 3 holes and remove

the metal chips.

 Mount the set screws [6570.2].

 Fix the set screws using a centre point.

6.9.8

Installing the mechanical seal

This procedure describes assembly of the
mechanical seal to the casing cover.

 Clean the supporting surfaces of the

mechanical seal and the casing cover.

 Place a new packing ring [see seal dwg.] in the

casing cover or O-ring on the seal plate,
dependent from the seal type.

 Place the mechanical seal in the casing cover

in accordance with the instructions for use
provided by the supplier.

 Tighten the nuts [6581.2] for fixing the

mechanical seal to the casing cover by
applying the prescribed torque, see section 6.5.

6.9.9

Fitting the bearing bracket


This procedure describes assembly of the bearing
bracket to the casing cover.

 Clean the mounting surfaces of the bearing

bracket and the casing cover.

 Carefully place the pump shaft in the shaft

sleeve so that the pump bracket is resting.

 Tighten the bolts [6577.5].

6.9.10 Fitting the impeller
This procedure describes assembly of the impeller
to the pump shaft.

 Attach the lifting devices to the appropriate

lifting points and observe the lifting instructions
described in section 2.3.

 Lift up the pump back pull-out unit as a single

assembly so that the end of the pump shaft is
easily accessible.

 Place the key [6700.1] in the pump shaft. See

Figure.

 Place a new packing ring [4590.3] against the

stub sleeve of the mechanical seal.

 Slide the impeller over the pump shaft.

 Fit a new packing ring [4590.1] according to

Figure.