PLEUGER STANDARD USER INSTRUCTIONS ENGLISH 71569293 01-13

Page 34 of 40

flowserve.com

Table 8-3

°C (°F)

°C (°F)

°C (°F)

1 (33.8)

100.39

36 (96.8)

113.86

71 (159.8)

127.34

2 (35.6)

100.77

37 (98.6)

114.25

72 (161.6)

127.72

3 (37.4)

101.16 38 (100.4) 114.63

73 (163.4)

128.11

4 (39.2)

101.54 39 (102.2) 115.02

74 (165.2)

128.49

5 (41.0)

101.93 40 (104.0) 115.40

75 (167.0)

128.88

6 (42.8)

102.31 41 (105.8) 115.79

76 (168.8)

129.26

7 (44.6)

102.70 42 (107.6) 116.17

77 (170.6)

129.65

8 (46.4)

103.08 43 (109.4) 116.56

78 (172.4)

130.03

9 (48.2)

103.47 44 (111.2) 116.94

79 (174.2)

130.42

10 (50.0)

103.85 45 (113.0) 117.33

80 (176.0)

130.80

11 (51.8)

104.24 46 (114.8) 117.71

81 (177.8)

131.19

12 (53.6)

104.62 47 (116.6) 118.10

82 (179.6)

131.57

13 (55.4)

105.01 48 (118.4) 118.48

83 (181.4)

131.96

14 (57.2)

105.39 49 (120.2) 118.87

84 (183.2)

132.34

15 (59.0)

105.78 50 (122.0) 119.25

85 (185.0)

132.73

16 (60.8)

106.16 51 (123.8) 119.64

86 (186.8)

133.11

17 (62.6)

106.55 52 (125.6) 120.02

87 (188.6)

133.50

18 (64.4)

106.93 53 (127.4) 120.41

88 (190.4)

133.88

19 (66.2)

107.32 54 (129.2) 120.79

89 (192.2)

134.27

20 (68.0)

107.70 55 (131.0) 121.18

90 (194.0)

134.65

21 (69.8)

108.09 56 (132.8) 121.56

91 (195.8)

135.04

22 (71.6)

108.47 57 (134.6) 121.95

92 (197.6)

135.42

23 (73.4)

108.86 58 (136.4) 122.33

93 (199.4)

135.81

24 (75.2)

109.24 59 (138.2) 122.72

94 (201.2)

136.19

25 (77.0)

109.63 60 (140.0) 123.10

95 (203.0)

136.58

26 (78.8)

110.01 61 (141.8) 123.49

96 (204.8)

136.96

27 (80.6)

110.40 62 (143.6) 123.87

97 (206.6)

137.35

28 (82.4)

110.78 63 (145.4) 124.26

98 (208.4)

137.73

29 (84.2)

111.17 64 (147.2) 124.64

99 (210.2)

138.12

30 (86.0)

111.55 65 (149.0) 125.03 100 (212.0) 138.50

31 (87.8)

111.94 66 (150.8) 125.41

32 (89.6)

112.32 67 (152.6) 125.80

33 (91.4)

112.71 68 (154.4) 126.18

34 (93.2)

113.09 69 (156.2) 126.57

35 (95.0)

113.48 70 (158.0) 126.95

8.4 Removal of the pump unit

When lifting the pump to withdraw it, take account of
the pump weight plus the weight of the water column
contained within the riser pipe if the pump unit does
not have a check valve with drain holes. (If the check
valve does have drain holes the weight of the water
column is not applicable.)

8.5 Overhaul of the pump unit

The structural design of a submersible pump unit
makes assembly and disassembly possible using
simple tools.

In case of removal, installation instructions specific to
the unit can be requested from the manufacturer. It is
recommended, however, that the unit is examined by
Flowserve technicians or that it is overhauled at a
Flowserve authorized service depot.

When taking the unit out of service and before
starting removal work, studying these operating
instructions once again is recommended.

For special advice regarding additional information or
for purchasing replacement parts, the following
information is required:

Serial number of the unit from the nameplate (also

printed on the stator housing)

Description of the unit type according to the

nameplate


For questions regarding replacement parts:

Item number from the sectional drawing

Part description and number as shown in the
parts list

Quantity of parts required


For problems:

Short description of the problem and or the effects

Description of the faulty part(s) as shown in the
parts list


Please refer all questions directly to the main factory
or to a factory representative.

Advertising