PLEUGER STANDARD USER INSTRUCTIONS ENGLISH 71569293 01-13

Page 36 of 40

flowserve.com

FAULT SYMPTOM

Motor protection triggered



Pump does not start



Motor overheats



Unit runs but does not pump



Unit vibrates or is noisy



Motor loses filling liquid



Pump requires excessive power



Pump does not draw in water at start



Insufficient pressure developed



Insufficient capacity developed



PROBABLE CAUSES

POSSIBLE REMEDIES

A. System problems



  

Abrasive solids in liquid pumped.

Check and consult Flowserve.

     

Internal misalignment due to improper repairs
causing impeller to rub.

Check method of assembly, possible damage
or state of cleanliness during assembly.

  

Excessive thrust caused by a mechanical
failure inside the pump.

Check wear condition of impeller, its
clearances and liquid passages.



 

Improper installation of bearings.

Check method of assembly, possible damage
or state of cleanliness during assembly and
type of bearing used.



 

Damaged bearings due to contamination.

Check contamination source and replace
damaged bearings.





 Slide valve not fully open.

Open slide valve.







 Pressure pipe clogged. Foreign body in the

pipe line.

Clean pipe work.

 



 Pump blocked by impurities inside the pump.

Disassemble pump section and clean.

    

 Pump or motor sluggish.

Check smooth running of motor/pump.





  Well filter clogged up.

Remove unit and regenerate well.

 

Coupling between pump and motor faulty.

Remove unit and repair.



 

   Suction strainer clogged up.

Remove unit and clean suction strainer.

C. Electrical problems

 

  Wrong direction of rotation of motor.

Reverse two phases at motor terminal box.



Motor circuit breaker incorrectly adjusted.

Readjust motor circuit breaker according to
data card or rating plate.

      

Motor running too slow. Under voltage or
wrong frequency.

Check if system voltage and frequency agree
with data sheet.

 

   Phase failure.

Examine power cable for damage. Check
fuses.

 

   Blown fuses.

Replace fuses.



 Damaged power cables.

Replace power cables.