2.3.2 Lifting of driver

Use driver lifting lugs/ or follow driver manufacturer’s

User Instructions.

A crane must be used for all pump sets in

excess of 25 kg (55 lb). Fully trained personnel must

carry out lifting, in accordance with local regulations.

The driver and pump weights to be noted before

lifting is attempted.

2.4 Storage

Store the pump in a clean, dry location

away from vibration. Leave piping connection covers

in place to keep dirt and other foreign material out of

pump casing. Turn pump at intervals to prevent

brinelling of the bearings and the seal faces (if fitted),

from sticking.

2.4.1 Inspection before storage

a) Inspect the preservative coating/painted surfaces

on the various parts. Touch up whereever

necessary.

b) Inspect all covers over pump openings and piping

connections. If found damaged, remove the

covers and inspect interiors of the opening for any

deposits of foreign materials or water.

c) If necessary, clean and preserve the interior parts

as noted above to restore the parts to the "as

shipped" condition. Replace covers and fasten

securely.

2.4.2 Short term storage (less than 6 months)

When it is necessary to store a pump for a short time

before it can be installed, place it in a dry location

and protect it thoroughly from moisture.

When protective flanges are bolted to the suction and

discharge nozzles at the factory, they should not be

removed. Protect the bearings and the shaft against

moisture, dirt, or other foreign matter. To prevent

rusting in or seizing, lubricate the unit; see Section

5.2,

Pump Lubricants

.

Rotate the pump shaft a

minimum of 5 revolutions every two weeks to keep

the bearings coated with lubricant and to minimize

the effects of brinelling.

MNV and MNZ standard pumps are

grease lubricated. Oil lubricated anti-friction bearings

are factory lubricated to prevent rusting for a short

period of time only. It is important to fill the

recommended oil lubricant to proper level

immediately upon receiving the equipment.

2.4.3 Long term storage (6 months and over)

More thorough precautions are required if

the pump is scheduled to be stored for an extended

period of time. Contact Flowserve before long-term

storage is attempted for specific storage

requirements and warranty information.

The following is a general procedure and could vary

depending upon the pump design and specific

application.

The storage area should be a clean

and dry. The storage location not be subjected to

rapid changes in temperature, light (no direct lighting)

or humidity, and relatively free of ground transmitted

vibration due to heavy construction and/or

machinery.

A temperature range of 5

o

to 50

o

C ( 40

o

to 120

o

F)

with non-condensing humidity is recommended.

a) Drain fluid from the pump, rotate the pump rotor

once in the proper direction and blow the liquid

end dry with air.

b) Coat the interior surfaces of the liquid end with

rust inhibitor by brushing, spraying or fogging.

Rotate the pump shaft one turn in the proper

direction while coating.

c) Remove the packing and seal cage from the

stuffing box to prevent corrosion due to

condensation. Coat the interior machined

surfaces of stuffing box with a rust inhibitor. This

step may be omitted if the pumps are stored prior

to initial use.

d) For grease lubricated bearing frames, fill the

cavity between the bearing covers and bearings

with a good grade of NGLI No. 2 lithium base

grease to prevent contamination of the bearings.

Ensure the bearings are thoroughly packed with

grease. Lubrication quality and quantity must be

checked every six months and replaced or

replenished as necessary.

e) Coat all threaded openings with rust inhibitor and

plug. Coat machined surfaces of exposed

flanges with rust inhibitor and then cover with

fiberboard or wood flange covers. Desiccant

bags should be secured to the covers prior to

putting them in place and must not contact metal

surfaces.

f) Coat exposed, unpainted, and machined

surfaces with a rust inhibitor.